Ventilation System Renovation for Campus Wuppertal

Status
Expired
Submission Deadline
No deadline specified
Contracting authority
BARMER Beschaffung und Vergabe24 more open tenders view
Location
Wuppertal, Germany
Procedure
Open Procedure · Works
Category
Ventilation installation work.
Published
Reference
ted-503048-2026

Renovation of ventilation systems: complete renovation of existing ventilation systems, with no existing systems remaining in the building distribution. The entire ventilation supply is realized via roof-mounted air handling units (AHUs) with a total air volume of approx. 165,000 m³/h, distributed among 14 units. Of these, 12 AHUs (galvanized system) each supply an office wing including ancillary areas on the ground floor across all levels. One unit is planned for the event room and another in stainless steel for the canteen/kitchen. Each unit is equipped with a cross-flow heat exchanger, air heater (fed by heating distribution), and air cooler with direct cooling (including direct evaporator, compressor, and condenser). The base design is 200 mm, positioned on steel platforms/beams, using refrigerant R513 A. The duct distribution for supply and exhaust air runs via the roof into 12 technical shafts per floor, located to the left and right of the stairwells. Fire protection compartmentalization with plinth fire dampers in the floor of each level is provided. For each office wing, distribution from these shafts leads into centrally arranged ceiling coffers, from which supply and exhaust air are provided via grilles with connection box combinations. Each grille includes a sound insulation and volume control combination within the coffer. Ancillary areas such as WCs and corridors are equipped with disc valves and swirl diffusers, while special areas like the canteen and event room feature slot diffusers. Ventilation is control-regulated based on carbon dioxide content in occupied rooms, with limited user intervention possible. Small systems are also part of the scope. Roof fans in PPs and galvanized systems are planned for BOS, BMA, and SIB control centers, the waste room, and for emergency supply and exhaust air for the chiller room. All duct systems must be insulated according to GEG specifications; fire protection measures and proper fastening technology must be considered.

Free

Missed this tender?

This deadline has passed. So it does not happen again: we send you 3 current matches that fit your company.

With a number we call briefly to sharpen your search profile.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email and, if you leave a number, calls you once about it. Revocable at any time. Privacy policy


Tender documents

  • Portal — LOT-0001NON-RESTRICTED-DOCUMENT
  • TED HTML — 503048-2026HTML
  • TED PDF — 503048-2026PDF
  • TED XML — 503048-2026XML
Free

Unlock documents for free

Enter your email address. If you confirm, we will also send you 3 similar tenders.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email. Free, unsubscribe anytime. Privacy policy


Additional details

EU Funded
Yes
Suitable for SMEs
No
Electronic Submission
Required
Legal Basis
32014L0024
Live webinar

See Patterno work on a real tender

45 minutes live, questions answered in the chat. Upcoming dates on the signup page.

  • Matches from 4,500+ portals in one workspace
  • Qualify any tender against your criteria in minutes
  • Prepare bid documents from your company context

Prefer a private session?