Locksmith Work for Interior Doors
Notice title: 3.031.2 Schlosserarbeiten Innentüren
Locksmith work for interior doors: 5 glazed steel tube frame doors without fire protection requirements, including vestibule and interior door elements with side panels, transoms, blind panels, pull handles, and slide rail overhead door closers; 10 glazed steel tube frame doors with fire and smoke protection requirements T30-RS and T90-RS, including approved fire protection glazing, smoke protection seals, retractable bottom seals, door closers, closing sequence controls, and, if required, hold-open devices and escape route fittings; 60 m² fixed glazed steel tube frame elements as a glass facade with fire protection requirements F30 and 2 insert elements as double-leaf door elements, including approved glazing, post-and-rail constructions, transoms, floor, wall, and ceiling connections; 5 single and double-leaf steel sheet doors as fire and smoke protection closures T30-RS and T90, including steel or steel wrap-around frames, necessary bottom seals, locks, lever/knob sets, door closers, and fire-compliant connections; 10 T90 maintenance doors on the technical floor as self-closing steel sheet doors for access to grid level maintenance fields.