Facade Works for Curtain-Ventilated Facade
Facade works for a curtain-ventilated facade: approx. 1,100 m² thermal insulation MW WLS 035 280-300 mm, approx. 820 m thermal insulation MW WLS 035, D 80-280 mm as strips, approx. 1,200 m² system-bound substructure in aluminum and stainless steel, approx. 35 m special substructure for facade termination on a PR facade, approx. 900 m² fiber cement panel D 8.0 mm, approx. 200 m² aluminum sheet cassette D 2.00 mm, approx. 30 m² substructure for soffit, approx. 30 m² aluminum sheet cassette D 2.00 mm, approx. 1,300 m finishing/ventilation sheet, approx. 250 m fire barrier, approx. 200 m prefabricated parapet capping profile in aluminum sheet D 3.0 mm, approx. 15 m substructure for facade termination, 10 pcs cover plate for facade termination in aluminum sheet D 3.00/2.00 mm, approx. 320 pcs permanent anchors, approx. 40 m perimeter insulation, and approx. 55 m plinth flashing in aluminum sheet D 1.0 mm.
CONTRACTING AUTHORITY
Name
Landeshauptstadt München, Baureferat
City
München
Country
DE
CLASSIFICATION
Procedure Type
Open Procedure
Contract Type
Works
Main CPV
45443000, Facade work.
Other CPV
45261300, Flashing and guttering work.
45262670, Metalworking.
45210000, Building construction work.
45216120, Construction work for buildings relating to emergency services.
45216121, Fire station construction work.
ADDITIONAL DETAILS
EU Funded
Yes
Suitable for SMEs
No
Electronic Submission
Required
Legal Basis
32014L0024
DEADLINES & TIMELINE
Submission Deadline
67 days remaining(LOT-0000)
Published