Skip to main content
All tenders

Delivery of patient immobilization devices

Status
Active
Submission Deadline
9 days remaining
Location
гр. София, Bulgaria
Estimated Value
€83,000
Procedure
Open Procedure · Supplies
Category
Miscellaneous medical devices and products.
Published
Reference
ted-503471-2026

Delivery of patient immobilization devices, compatible with Varian TrueBeam EDGE 6D couch, Varian Clinac IX patient table, Siemens Somatom Definiton AS CT scanner, and Accuray Tomotherapy HDA helical tomotherapy system: 3 basic fiber carbon base plates for 'push-pin' masks with rectangular insert for headrests; 3 complete sets of foam headrests with various curvatures for supine and prone positions; 3 sets of blocks and wedges for height and inclination adjustment of headrests; 3 positioning wedges for breast irradiation made of foam with armrests and tilt adjustment, including lifting wedges of 5° and 10° (combinable for 15° lift) and a system for arm positioning above the head; 3 immobilization systems for thoracic irradiation ('wing board') with arm positioning above the head; 3 knee and foot positioning systems made of foam, comprising a knee fixation wedge and foot fixation; bolus of gelled gel: 5 units 30x30x5 mm unpackaged, 5 units 30x30x5 mm packaged, 5 units 30x30x10 mm unpackaged, 5 units 30x30x10 mm packaged; 1 thermostatic bath for thermoplastic masks (min. internal dimensions 660 mm x 550 mm); thermoplastic masks: 50 microperforated head immobilization masks with 3-point attachment, 250 microperforated head, neck, and shoulder immobilization masks with 5-point attachment, 50 microperforated, RX-reinforced head, neck, and shoulder immobilization masks ('open face') with 3-point attachment, 30 microperforated, RX-reinforced head, neck, and shoulder immobilization masks ('open face') with 5-point attachment, 50 thermoplastic abdomen and pelvis immobilization masks with 4-point attachment, 50 microperforated, RX-reinforced head, neck, and shoulder immobilization masks (front and back part) compatible with Encompass base plate; 4 locating bars with 10 cm left-right displacement, suitable for Varian TrueBeam EDGE accelerator, Varian Clinac IX accelerator, Siemens Somatom Definiton AS CT scanner, and Accuray Tomotherapy HDA helical tomotherapy system. Samples for items 9.1 to 9.6 must be submitted. further items as per the tender documents.

Free

Never miss a tender again

We send you 3 current matches that fit your company.

With a number we call briefly to sharpen your search profile.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email and, if you leave a number, calls you once about it. Revocable at any time. Privacy policy


Tender documents

  • Portal — LOT-0001NON-RESTRICTED-DOCUMENT
  • TED HTML — 503471-2026HTML
  • TED PDF — 503471-2026PDF
  • TED XML — 503471-2026XML
Free

Unlock documents for free

Enter your email address. If you confirm, we will also send you 3 similar tenders.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email. Free, unsubscribe anytime. Privacy policy


Additional details

EU Funded
Yes
Electronic Submission
Required
Legal Basis
32014L0024
Live webinar

See Patterno work on a real tender

45 minutes live, questions answered in the chat. Upcoming dates on the signup page.

  • Matches from 4,500+ portals in one workspace
  • Qualify any tender against your criteria in minutes
  • Prepare bid documents from your company context

Prefer a private session?