Skip to main content
All tenders

Physico-chemical Analyses for Environmental Matrices

Status
Active
Submission Deadline
33 days remaining
Contracting authority
Location
Liège, Belgium
Procedure
Open Procedure · Services
Category
Survey analysis services.
Published
Reference
ted-547581-2026

Physico-chemical analyses for soils and sediments: PFAS according to technical protocol CMA/3/D, PFAS leaching according to CMA/2/II/A.26, PFAS analysis on eluate according to WAC/IV/A/025, Trifluoroacetic acid (TFA) analysis on eluate (CAS 76-05-1) according to WAC/IV/A/026, pH-KCl acidity, organic matter content (loss on ignition), granulometry in 5 fractions (<2,<16,<45,<63 and<2000 µm), and parameters according to Annex 1 of the Soil Decree of 01/03/2018 (with phenol index instead of phenol). The technical protocols are available via https://emis.vito.be/nl/erkende-laboratoria/bodem-en-afvalstoffen-ovam/compendium-cma and https://emis.vito.be/nl/erkende-laboratoria/water/compendium-wac and may evolve during the contract period; the latest available version must always be observed. Quantification limits must be specified for each parameter, except for leaching as a pre-treatment. Results are to be transmitted to ISSeP in specified formats. Samples are stored in the laboratory until receipt and validation of results by ISSeP, then disposed of by the laboratory. Random controls of transmitted results by ISSeP may be carried out. A required option includes the provision of urgent analyses (within 24 h, 48 h, or 72 h) with specification of the corresponding percentage surcharge on the analysis price.

Free

Never miss a tender again

We send you 3 current matches that fit your company.

With a number we call briefly to sharpen your search profile.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email and, if you leave a number, calls you once about it. Revocable at any time. Privacy policy


Tender documents

  • Portal — LOT-0001NON-RESTRICTED-DOCUMENT
  • TED HTML — 547581-2026HTML
  • TED PDF — 547581-2026PDF
  • TED XML — 547581-2026XML
Free

Unlock documents for free

Enter your email address. If you confirm, we will also send you 3 similar tenders.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email. Free, unsubscribe anytime. Privacy policy


Lots (3)

  • LOT-0001Dosierung von Schadstoffen und physikalisch-chemischen Parametern in Böden und Sedimenten
  • LOT-0002Dosierung von Schadstoffen und physikalisch-chemischen Parametern in Grund-, Oberflächen- oder Abwasser
  • LOT-0003Dosierung von Schadstoffen und physikalisch-chemischen Parametern in Düngemitteln

Additional details

EU Funded
Yes
Electronic Submission
Required
Legal Basis
32014L0024
Live webinar

See Patterno work on a real tender

45 minutes live, questions answered in the chat. Upcoming dates on the signup page.

  • Matches from 4,500+ portals in one workspace
  • Qualify any tender against your criteria in minutes
  • Prepare bid documents from your company context

Prefer a private session?