Technical Insulation for New Construction of Nursing Building BT C + D of kbo-Inn-Salzach-Klinikum
Technical insulation for nursing buildings BT C and D of the kbo-Inn-Salzach-Klinikum. Building Section C includes insulation work for sanitary, heating, cooling, and ventilation systems. For sanitary, 4,500 m thermal insulation mineral wool aluminum-laminated DN 12 to DN 65, 400 m thermal insulation mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 50, 90 m thermal insulation mineral wool diffusion-tight for rainwater DN 125 to DN 150, 50 m thermal insulation synthetic rubber with sheet metal casing DN 65 to DN 80, and 350 units valve insulation shells DN 15 to DN 50 are planned. Heating insulation comprises 7,400 m mineral wool aluminum-laminated DN 12 to DN 125, 750 m mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 125, 90 m mineral wool diffusion-tight DN 40 to DN 50, 40 m mineral wool diffusion-tight with sheet metal casing DN 40 to DN 50, 570 units valve insulation shells DN 15 to DN 50, and 140 units sheet-metal clad mineral fiber half-shells DN 15 to DN 125. For cooling, 1,100 m thermal insulation mineral wool diffusion-tight DN 20 to DN 80, 240 m mineral wool diffusion-tight with sheet metal casing DN 25 to DN 80, 1,000 m synthetic rubber DN 12 to DN 150, 320 m synthetic rubber with sheet metal casing DN 20 to DN 150, 28 units valve insulation mineral wool diffusion-tight DN 15 to DN 65, 28 units valve insulation mineral wool diffusion-tight with sheet metal casing DN 15 to DN 65, 170 units valve insulation synthetic rubber DN 12 to DN 150, and 76 units valve insulation synthetic rubber with sheet metal casing DN 15 to DN 150 are required. Ventilation insulation includes 2,100 m² insulation for air ducts and fittings mineral wool, 310 m² insulation for air ducts and fittings mineral wool with sheet metal cladding, 90 m² insulation for air ducts and fittings synthetic rubber, 200 m insulation for air lines up to DN 250 mineral wool, 130 units insulation for fittings up to DN 250 mineral wool, 5 m insulation for air lines up to DN 160 synthetic rubber, and 6 units insulation for fittings up to DN 160 synthetic rubber. Building Section D includes insulation work for sanitary, heating, cooling, and ventilation systems. For sanitary, 4,500 m thermal insulation mineral wool aluminum-laminated DN 12 to DN 65, 400 m thermal insulation mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 50, 90 m thermal insulation mineral wool diffusion-tight for rainwater DN 125 to DN 150, and 350 units valve insulation shells DN 15 to DN 50 are planned. Heating insulation comprises 6,000 m mineral wool aluminum-laminated DN 12 to DN 125, 660 m mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 125, 70 m mineral wool diffusion-tight DN 40 to DN 50, 40 m mineral wool diffusion-tight with sheet metal casing DN 40 to DN 50, 550 units valve insulation shells DN 15 to DN 50, and 130 units sheet-metal clad mineral fiber half-shells DN 15 to DN 125. For cooling, 1,100 m thermal insulation mineral wool diffusion-tight DN 20 to DN 80, 240 m mineral wool diffusion-tight with sheet metal casing DN 25 to DN 80, 1,000 m synthetic rubber DN 12 to DN 150, 320 m synthetic rubber with sheet metal casing DN 20 to DN 150, 28 units valve insulation mineral wool diffusion-tight DN 15 to DN 65, 26 units valve insulation mineral wool diffusion-tight with sheet metal casing DN 15 to DN 65, 170 units valve insulation synthetic rubber DN 12 to DN 150, and 76 units valve insulation synthetic rubber with sheet metal casing DN 15 to DN 150 are required. Ventilation insulation includes 1,600 m² insulation for air ducts and fittings mineral wool, 230 m² insulation for air ducts and fittings mineral wool with sheet metal cladding, 80 m² insulation for air ducts and fittings synthetic rubber, 190 m insulation for air lines up to DN 250 mineral wool, 100 units insulation for fittings up to DN 250 mineral wool, 5 m insulation for air lines up to DN 160 synthetic rubber, and 6 units insulation for fittings up to DN 160 synthetic rubber. Building Section F, assigned to BT C, includes cooling installations with 40 m thermal insulation mineral wool diffusion-tight DN 15 to DN 200, 150 m mineral wool diffusion-tight with sheet metal casing DN 15 to DN 200, 20 m synthetic rubber with sheet metal casing DN 125 to DN 200, 29 units valve insulation mineral wool diffusion-tight DN 15 to DN 65, 58 units valve insulation mineral wool diffusion-tight with sheet metal casing DN 15 to DN 65, and 9 units valve insulation synthetic rubber with sheet metal casing DN 125 to DN 200.
Never miss a tender again
We send you 3 current matches that fit your company.
Tender documents
- Portal — LOT-0001NON-RESTRICTED-DOCUMENT
- TED HTML — 580426-2026HTML
- TED PDF — 580426-2026PDF
- TED XML — 580426-2026XML
Unlock documents for free
Enter your email address. If you confirm, we will also send you 3 similar tenders.