Skip to main content
All tenders

Technical Insulation for New Construction of Nursing Building BT C + D of kbo-Inn-Salzach-Klinikum

Status
Active
Submission Deadline
32 days remaining
Contracting authority
Location
Wasserburg, Germany
Procedure
Open Procedure · Works
Category
Insulation work.Sound insulation work.
Published
Reference
ted-580426-2026

Technical insulation for nursing buildings BT C and D of the kbo-Inn-Salzach-Klinikum. Building Section C includes insulation work for sanitary, heating, cooling, and ventilation systems. For sanitary, 4,500 m thermal insulation mineral wool aluminum-laminated DN 12 to DN 65, 400 m thermal insulation mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 50, 90 m thermal insulation mineral wool diffusion-tight for rainwater DN 125 to DN 150, 50 m thermal insulation synthetic rubber with sheet metal casing DN 65 to DN 80, and 350 units valve insulation shells DN 15 to DN 50 are planned. Heating insulation comprises 7,400 m mineral wool aluminum-laminated DN 12 to DN 125, 750 m mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 125, 90 m mineral wool diffusion-tight DN 40 to DN 50, 40 m mineral wool diffusion-tight with sheet metal casing DN 40 to DN 50, 570 units valve insulation shells DN 15 to DN 50, and 140 units sheet-metal clad mineral fiber half-shells DN 15 to DN 125. For cooling, 1,100 m thermal insulation mineral wool diffusion-tight DN 20 to DN 80, 240 m mineral wool diffusion-tight with sheet metal casing DN 25 to DN 80, 1,000 m synthetic rubber DN 12 to DN 150, 320 m synthetic rubber with sheet metal casing DN 20 to DN 150, 28 units valve insulation mineral wool diffusion-tight DN 15 to DN 65, 28 units valve insulation mineral wool diffusion-tight with sheet metal casing DN 15 to DN 65, 170 units valve insulation synthetic rubber DN 12 to DN 150, and 76 units valve insulation synthetic rubber with sheet metal casing DN 15 to DN 150 are required. Ventilation insulation includes 2,100 m² insulation for air ducts and fittings mineral wool, 310 m² insulation for air ducts and fittings mineral wool with sheet metal cladding, 90 m² insulation for air ducts and fittings synthetic rubber, 200 m insulation for air lines up to DN 250 mineral wool, 130 units insulation for fittings up to DN 250 mineral wool, 5 m insulation for air lines up to DN 160 synthetic rubber, and 6 units insulation for fittings up to DN 160 synthetic rubber. Building Section D includes insulation work for sanitary, heating, cooling, and ventilation systems. For sanitary, 4,500 m thermal insulation mineral wool aluminum-laminated DN 12 to DN 65, 400 m thermal insulation mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 50, 90 m thermal insulation mineral wool diffusion-tight for rainwater DN 125 to DN 150, and 350 units valve insulation shells DN 15 to DN 50 are planned. Heating insulation comprises 6,000 m mineral wool aluminum-laminated DN 12 to DN 125, 660 m mineral wool aluminum-laminated with sheet metal casing DN 12 to DN 125, 70 m mineral wool diffusion-tight DN 40 to DN 50, 40 m mineral wool diffusion-tight with sheet metal casing DN 40 to DN 50, 550 units valve insulation shells DN 15 to DN 50, and 130 units sheet-metal clad mineral fiber half-shells DN 15 to DN 125. For cooling, 1,100 m thermal insulation mineral wool diffusion-tight DN 20 to DN 80, 240 m mineral wool diffusion-tight with sheet metal casing DN 25 to DN 80, 1,000 m synthetic rubber DN 12 to DN 150, 320 m synthetic rubber with sheet metal casing DN 20 to DN 150, 28 units valve insulation mineral wool diffusion-tight DN 15 to DN 65, 26 units valve insulation mineral wool diffusion-tight with sheet metal casing DN 15 to DN 65, 170 units valve insulation synthetic rubber DN 12 to DN 150, and 76 units valve insulation synthetic rubber with sheet metal casing DN 15 to DN 150 are required. Ventilation insulation includes 1,600 m² insulation for air ducts and fittings mineral wool, 230 m² insulation for air ducts and fittings mineral wool with sheet metal cladding, 80 m² insulation for air ducts and fittings synthetic rubber, 190 m insulation for air lines up to DN 250 mineral wool, 100 units insulation for fittings up to DN 250 mineral wool, 5 m insulation for air lines up to DN 160 synthetic rubber, and 6 units insulation for fittings up to DN 160 synthetic rubber. Building Section F, assigned to BT C, includes cooling installations with 40 m thermal insulation mineral wool diffusion-tight DN 15 to DN 200, 150 m mineral wool diffusion-tight with sheet metal casing DN 15 to DN 200, 20 m synthetic rubber with sheet metal casing DN 125 to DN 200, 29 units valve insulation mineral wool diffusion-tight DN 15 to DN 65, 58 units valve insulation mineral wool diffusion-tight with sheet metal casing DN 15 to DN 65, and 9 units valve insulation synthetic rubber with sheet metal casing DN 125 to DN 200.

Free

Never miss a tender again

We send you 3 current matches that fit your company.

We call you once briefly to sharpen your search profile.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email. Free, unsubscribe anytime. Privacy policy


Tender documents

  • Portal — LOT-0001NON-RESTRICTED-DOCUMENT
  • TED HTML — 580426-2026HTML
  • TED PDF — 580426-2026PDF
  • TED XML — 580426-2026XML
Free

Unlock documents for free

Enter your email address. If you confirm, we will also send you 3 similar tenders.

We call you once briefly to sharpen your search profile.

No account neededReply in 1-2 business days

By submitting, you agree that Patterno sends you matching tenders by email. Free, unsubscribe anytime. Privacy policy


Additional details

EU Funded
Yes
Suitable for SMEs
Yes
Electronic Submission
Required
Legal Basis
32014L0024
Live webinar

See Patterno work on a real tender

45 minutes live, questions answered in the chat. Upcoming dates on the signup page.

  • Matches from 4,500+ portals in one workspace
  • Qualify any tender against your criteria in minutes
  • Prepare bid documents from your company context

Prefer a private session?